how to restart laser cutting machine equipment-Ivy

Hi,here sharing with something we should pay more attention about how to restart laser cutting machine equipment.

1: power checking:

Before powering on the device, you need to check whether the switch is well and whether the line is broken or the contact is poor.

2: machine tool preparation

Start the operating software, and manually move the X, Y, and Z axes to test whether the performance of the machine tool is normal and the machine tool returns to the mechanical origin. Before returning to zero, make sure that the workbench is free of debris.

3: laser preparation

After checking power supply , the laser turn on. (You only need to turn on the power switch and do not need to twist the key or the laser power start button.) Wait 30 minutes for the laser to perform smoothly.

4: water cooler preparation

Before adding water, make sure that the drain valve is close. Observe the operating conditions when turning on the water cooler. At the same time check the laser / cutting head water pipe joints and the interior for leaks, and ensure that there are no leaks in other waterways of the machine.

5: gas inspection

Before starting to run the equipment, remember to check that the gas control valve is open, and manually test the gas before cutting to ensure that the cutting gas is normal before production.

6: Matters needing attention for air compressor

1. Check if the air compressor is wet by rain, and do not turn on the machine immediately when it is wet.
2. Check whether the external power of the air compressor and the dryer is normal.
3. Check if the circuit inside the compressor is damaged or loose.
4. Check whether the oil level of the air compressor is within the normal range.
5. Drain the condensate from the air compressor, air storage tank, cold dryer, and precision filter.
6. Because the air compressor is in a shutdown state for a long time, all the lubricating oil in the system is stored in the gasoline barrel. At this time, the fluidity of the lubricating oil at startup is poor, which may cause high temperature alarms and other failures at startup.

7. It is recommended to start by jogging for the first time.

The specific operations are as follows:
(1) Turn on the emergency stop button and power on for 5 minutes;
(2) Press the start button and run for 8 seconds;
(3) Press the stop button, turn off the emergency stop button and wait for 30 seconds;
(4) Repeat “start” and “stop” at least three times;
(5) Start up and run for 15 minutes, and the air compressor can be used normally after running normally.

    Teklif Al

    Need Help?

    Fill out the form below and support will be available within the hour!