Cause analysis of abnormal reset of laser cutting machine-Flora

Cause analysis of abnormal reset of laser cutting machine

Cause analysis of abnormal reset of laser cutting machine

The laser cutting machine often has problems with engraving and initialization, so we need to do it here. The following data correction can solve the problem.
Missing engraving of the laser cutting machine, incorrect initialization, data has been sent (corrected); the order of operation is reversed (re-enter); electrostatic interference (check whether the ground wire is off); the cleaning hook is misplaced and not closed, check whether the software parameter settings are correct ( Reset); the computer system is wrong (reinstall the operating system and software).

Besides, check whether the left and right belts are the same or whether the rear belt is too loose (belt tightening); check whether the belt or synchronization wheel is slipping or jumping teeth (tighten the synchronization wheel or Belt); check whether the beam is parallel (re-adjust the left and right belts).
The reasons for the abnormal reset of the laser cutting machine include the following aspects:
First, the X-axis and Y-axis of the laser cutting machine move in opposite directions and hit the side end. For this phenomenon, check whether the main board parameters are wrong, and stop the machine to check whether the main board parameter settings are wrong.
Second, the control panel of the laser cutting machine is displayed normally, and the X-axis and Y-axis do not move. You can try to unplug the sensor terminal of the motherboard to see if the machine is moving. In this case, consider replacing the sensor.
Third, the beam is reset normally, and the X axis of the laser cutting machine does not move. The motor wire or the motor shaft may be broken. For this phenomenon, the motor wire or small motor must be replaced.
Fourth, the direction is correct when resetting, but the X-axis or Y-axis cannot stop when it reaches the apex (check the motherboard parameters first). If it is correct, check the motherboard or sensor and replace and eliminate this phenomenon.

XT laser is manufacturer of laser  machines  since 2004, any inquiry, feel free to contact us:

Email: xintian131@xtlaser.com

Skype: XTlaser-Flora

Mobile/Whatsapp/Wechat:0086 18354256184

Web: www.xtlaser.com

    DEMANDER UN DEVIS

    Besoin d'aide ?

    Remplissez le formulaire ci-dessous et l'assistance sera disponible dans l'heure qui suit !